[kernel] power: rk81x-battery: fix charge termination voltage define error
the charge termination voltage configration is like bellow: 000: 4.05v, 001: 4.10v, 010: 4.15v 011: 4.20v, 100: 4.25v, 101: 4.30v 110: 4.35v, 111: 4.35v Change-Id: I17c7df5952c3913eaf509ae2603f2d96d7ea96c8 Signed-off-by: Firefly <service@t-firefly.com> (cherry picked from commit 231c34138efb7182dd82d5b392643c555b3ed285)
This commit is contained in:
@ -165,7 +165,7 @@ module_param_named(dbg_level, dbg_enable, int, 0644);
|
||||
/*
|
||||
* the following table value depends on datasheet
|
||||
*/
|
||||
int CHRG_V_LMT[] = {4050, 4100, 4150, 4200, 4300, 4350};
|
||||
int CHRG_V_LMT[] = {4050, 4100, 4150, 4200, 4250, 4300, 4350};
|
||||
|
||||
int CHRG_I_CUR[] = {1000, 1200, 1400, 1600, 1800, 2000,
|
||||
2250, 2400, 2600, 2800, 3000};
|
||||
|
||||
Reference in New Issue
Block a user